Page 230 - PHU_User Manual_EN_Rev A
P. 230

PHU Series User Manual

               Efficiency *14    200 Vac   %  86 to 94
               Hold-up time                 10 ms or greater

               Input Characteristics for PHU-C series (for 10kW models)

               Model                    PHU-C models
                                           3-Phase, 200 V models: 180 Vac to 265 Vac
               Nominal input rating
                                           (Covers 200/ 230 Vac)
               Input frequency range         47 Hz to 63 Hz
               Maximum input current  200Vac   A  56 A (L1), 32 A (L2, L3)
               Inrush current   200Vac   A  Less than 100 A
               Maximum input power       VA  12000
               Power factor    Rated Power     > 0.95
               Efficiency *14    200 Vac   %  86 to 94
               Hold-up time                 10 ms or greater


               Input Characteristics for PHU-C series (for 15kW models)

               Model                    PHU-C models
                                           3-Phase, 200 V models: 180 Vac to 265 Vac
               Nominal input rating
                                           (Covers 200/ 230 Vac)
               Input frequency range         47 Hz to 63 Hz
               Maximum input current  200Vac   A  56 A (L1, L2, L3)
               Inrush current   200Vac   A  Less than 100 A
               Maximum input power       VA  18000
               Power factor    Rated Power     > 0.95
               Efficiency *14    200 Vac   %  86 to 94
               Hold-up time                 10 ms or greater


               Input Characteristics for PHU-D series (for 5kW models)

               Model                    PHU-D models
                                           3-Phase, 400 V models: 342 Vac to 528 Vac
               Nominal input rating
                                           (Covers 380/400/415/440/460/480 Vac)
               Input frequency range         47 Hz to 63 Hz
               Maximum input current  400Vac   A  16 A (L1, L2)
               Inrush current   400Vac   A  Less than 25 A
               Maximum input power       VA  6000
               Power factor    Rated Power     > 0.95
               Efficiency *14    400 Vac   %  87 to 94
               Hold-up time                 10 ms or greater